Sign In | Join Free | My fazendomedia.com
China Sichuan Vacorda Instruments Manufacturing Co., Ltd logo
Sichuan Vacorda Instruments Manufacturing Co., Ltd
23 Years Focused on Level Measurement in Extreme Process Conditions
Active Member

6 Years

Home > Vortex Flow Meter >

Inline Vortex Water Flow Meter With Analog Signal Output

Sichuan Vacorda Instruments Manufacturing Co., Ltd

Inline Vortex Water Flow Meter With Analog Signal Output

  • 1
  • 2
  • 3

Place of Origin : Sichuan, China (Mainland)

Brand Name : Vacorda

Model Number : LUGB

Supply Ability : 100 Piece/Pieces per Week

Packaging Details : International trade wooden cases

MOQ : 1 Piece/Pieces

Price : Negotiable

Certification : CE/TUV/ISO9001/SGS

Medium : liquid,gas,steam

Fluid Temperature : -40~320℃

Nominal Pressure : 1.0~6.3Mpa

Accuracy : liquid:1.0,gas:1.5 insertion type :2.5

Power supply : 12V,24VDC,3.6lithium

Output : Pulse+4-20mADC, RS485, HART

Connection Size : Tube Type: DN15-DN300 Insertion Type: DN200-DN1500

Protection grade : IP65

Explosion-proof grade : EX II BT4Gb, EXI II aBT4Ga

keyword : inline vortex water flow meter

Port : Shanghai/Shenzhen

Contact Now

Inline Vortex Water Flow Meter With Analog Signal Output

Product Description

Vortex flowmeter is designed for measuring the volume/mass flow of liquids, gases and steam based on Karman vortex principle. Adopting advanced differential algorithm along with measurement of isolation, shielding and wave filtering, vortex flow meters have the advantages of immunity on vibration and noise. Meanwhile, the liabilities of LUGB series vortex flow meters are well guaranteed by unique sensor packaging technology. Upon receipt, examine your meter for visible damage. The Vortex is a precision measuring instrument and should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items are damaged or missing, contact us. Make sure the Vortex flow model meets your specific needs.

Features

1.High accuracy and good repeatability

2.The detection element has no contact with the fluid, and has stable performance and high reliability.

3.The structure is simple and firm, movable parts, and reliable in long-term operation.

4.The measuring range is wide that can up to 1:10 (special up to 15).

5.The pressure loss is small, about 1/4~1/2 of the orifice flowmeter

Scope of application

It is widely used in large, medium and small types of pipeline drainage, industrial circulation, sewage treatment, oil and chemical reagents, and the measurement of compressed air, saturated, overheated steam, natural gas and other medium flow.

Inline Vortex Water Flow Meter With Analog Signal Output

flange type flange clamping type

Product Parameters

(1)Measuring medium

liquid,gas,steam

(2) Medium velocity

luquid:0.5~7,gas:4~40,steam:7~70m/s

(3) Accuracy

liquid:1.0,gas:1.5,insertion type:2.5

(4) Nominal size

DN15~DN300(Pipe type,Gripping type)

DN150~DN2000(insertion type)

(5)Medium temperature

-40℃~80℃,Middle temperature:-40℃~250℃,High temperature:-40℃~350℃

(6) Nominal pressure

1.0~6.3Mpa(>6.3 Customizable)

(7)Installation method

flange,Clamping,insertion

(8)signal output Pulse+4-20mADC, RS485, HART

(9)Power Supply

12V,24VDC(Three line pulse output)

24VDC(Two wire power supply)

3.6V lithium 7.5AH battery,2years lifetime(on the spot display)

(8) Electrical interface

M20x1.5,1.2''NPT

(9) Body material

304.316L(Customizable)

(10)head material

Cast aluminum shell,Stainless steel shell(Customizable)

(11)Protection grade IP65

(12) Explosion-proof grade EX II BT4Gb, EXI II aBT4Ga

Detailed Images

Inline Vortex Water Flow Meter With Analog Signal OutputInline Vortex Water Flow Meter With Analog Signal OutputInline Vortex Water Flow Meter With Analog Signal Output

Measurabe Flow Rate Range

Note: the flow range a below is foe reference only. Consult us if you have special requirement.

Refer to the nameplate or certificate for actual flow rang

diameter

(mm)

liquid

flow(m3/h)

air(Standard state)

flow(Nm3/h)

15 0.6~6.0 6~40
20 1.0~8.0 8~50
25 1.3~13 10~80
32 1.5~15 14~120
40 3~30 25~250
50 4~40 30~300
65 6~60 50~500
80 13~130 80~800
100 20~200 20~1200
125 36~360 160~1600
150 50~500 250~2500
200 100~1000 400~4000
250 150~1500 600~6000
300 200~2000 1000~10000

Intallation

Cautions for installation

Inline Vortex Water Flow Meter With Analog Signal Output

Rquired Lengths of Straight Run

Inline Vortex Water Flow Meter With Analog Signal Output

The recommended guidelines are given to enhance accuracy and maximize performance. Distance given here are minimum requirements; double them for desire straight pipe lengths.

• Upstream: allow a minimum straight pipe length at least 10 times the internal diameter of the pipe.

For example, with the 50mm pipe ,there should be 500mm of straight pipe immediately upstream.

Desired upstream straight pipe length is 500mm.

• Downstream:allow a minimum straight pipe length at least 5 times teh internal diameter of the pipe. For example, with the 50mm pipe , there should be 250mm of straight pipe immediately upstream. Desired upstream straight pipe is 500mm.

Product Application


Product Tags:

vortex type flow meter

      

vortex flow sensor

      
Best Inline Vortex Water Flow Meter With Analog Signal Output wholesale

Inline Vortex Water Flow Meter With Analog Signal Output Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sichuan Vacorda Instruments Manufacturing Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)